Maps of die failure types for the 6-in Honeywell SVX3D wafers

Click on the wafer number in the table below to get its map of die failures in Postscript. Standard 6-in wafer quality maps are here.

In the maps below failure types are color coded. As in the wafer quality maps, green and yellow mean good and fair dies, correspondingly. Other colors signify various die failure modes. The failures are categorized as follows:

Currents  :  AVDD or DVDD supply currents are too high.
Serial  :  serial line failures.
Basic readout  :  incorrect readback structure.  Bad chip id, invalid channel number sequence, etc.
Pipeline logic  :  failures in the pipeline logic. Unexpected cell ids in various operation modes.
Analog  :  a wide class of failures which include out-of-range pedestals, gains, noise, etc.
Operator  :  die is classified as bad by an operator of the wafer probing setup. This may happen when the classification program encounters a failure pattern which is either unusual or could be due to wafer misalignment. In such a case the operator may perform an interactive test of the die functionality.  
 
 Wafer # 
 Manufacturer # 
69
Y21316-11-20
70
Y21316-08-03
72
Y21316-10-08
74
Y21316-09-03
76
Y21316-12-04
80
Y21316-12-15
81
Y21316-11-03
82
Y21316-12-11
83
Y21316-11-18
85
Y21316-08-04
87
Y21316-08-01
89
Y21316-10-02
91
Y21316-10-01
92
Y21316-09-02
93
Y21316-09-05
137
Y21316-12-12
138
Y21316-11-11
140
Y21316-08-17
141
Y21316-08-06
142
Y21316-08-11
143
Y21316-08-15
144
Y21316-11-05
145
Y21316-10-18
146
Y21316-10-10
147
Y21316-12-14


Questions? E-mail to igv@lbl.gov